IG03 SIG16 Energy management systems
Scope
This SIG develops and maintains technical documents for energy management systems that may operate in mobile applications (e.g. light-electric vehicles) as well as non-mobile applications (e.g. isolated farms).
Chair
Steffen Rose, emotas
Meetings
Minutes
Name | Date | Size | Action |
---|---|---|---|
IG03 SIG16 Energy management systems | 2019-04-03 | 395 KB | Login |
IG03 SIG16 Energy management systems | 2019-06-07 | 3 MB | Login |
IG03 SIG16 Energy management systems | 2019-09-11 | 1 MB | Login |
IG03 SIG16 Energy management systems | 2019-10-14 | 3 MB | Login |
IG03 SIG16 Energy management systems | 2019-12-19 | 114 KB | Login |
IG03 SIG16 Energy management systems | 2020-03-26 | 125 KB | Login |
IG03 SIG16 Energy management systems | 2020-04-30 | 621 KB | Login |
IG03 SIG16 Energy management systems | 2020-06-04 | 115 KB | Login |
IG03 SIG16 Energy management systems | 2019-11-13 | 2 MB | Login |
IG03 SIG16 Energy management systems | 2024-03-15 | 86 KB | Login |
IG03 SIG16 Energymanagement systems | 2024-06-04 | 575 KB | Login |
Title | Details | Published Size |
Status Action |
---|---|---|---|
CiA 312-7 version 1.0.0 CANopen profile conformance test plans - Part 7: Pedelec Profile 1 |
ScopeThis document provides the conformance test specification for devices implemented according to CiA 454, Part 1, 2, 3, 4, 5, and 6 version 2.0. 2 Normative references CiA 301, CANopen application layer and communication profile; CiA 305, CANopen layer setting services (LSS) and protocols; CiA 306, CANopen electronic device description; CiA 310, Conformance test plan – CiA 301 testing; CiA 454, CANopen application profile for energy management systems. NOTE Some parts of CiA 454 were submitted to IEC for international standardization in IEC 61851-3 Electric vehicle conductive charging system |
2020-03-30 568 KB | DSP Login |
CiA 454-7 version 1.0.0 CANopen application profile for energy management systems - Part 7: Drive control unit |
ScopeThis document specifies application objects provided by the drive control unit, as typically utilized in light electric vehicles. |
2021-04-06 665 KB | DSP Login |
CiA 454-9 version 1.0.0 CANopen application profile for energy management systems - Part 9: HMI unit |
ScopeThis document specifies application objects provided or indicated by human machine interface units, as typically utilized in light electric vehicles. This comprises human machine interface units, managing data for signalling, travelling, battery systems, inputs for energy management user condition and state, motion and diagnostics. |
2021-04-06 283 KB | DSP Login |
CiA 454-13 version 1.0.0 CANopen application profile for energy management systems - Part 13: Generator unit |
ScopeThe CANopen application profile for EMSs specifies the communication interface for all virtual devices that may take part in energy management control application. Such energy management control applications may be implemented in e.g. light electric vehicles, robots, offshore parks, isolated farms, etc. The CANopen application profile for EMSs consists of the following parts: Part 1: General definitions, Part 2: Pre-defined communication parameters and general application objects, Part 3: Pre-defined PDO communication, Part 4: EMS controller, Part 5: Voltage converter unit, Part 6: Battery pack, Part 7: Motor control unit (under development), Part 8: Load monitoring unit (under development), Part 9: HMI unit (under development), Part 10: Security unit (under development), Part 11: Sensor unit (under development), Part 12: Gateway unit (under development), Part 13: Generator unit, Part 14: Load unit. This document represents the part 13 of the CANopen application profile for EMSs. Part 13 of the document specifies generator units such as a diesel engine, photovoltaic generator, winds turbine, etc. Generators shall be divided into two classes: Controllable and stochastic generator. |
2014-06-17 533 KB | DSP Login |
CiA 454-14 version 1.0.0 CANopen application profile for energy management systems - Part 14: Load unit |
ScopeThe CANopen application profile for EMSs specifies the communication interface for all virtual devices that may take part in energy management control application. Such energy management control applications may be implemented in e.g. light electric vehicles, robots, offshore parks, isolated farms, etc. The CANopen application profile for EMSs consists of the following parts: Part 1: General definitions, Part 2: Pre-defined communication parameters and general application objects, Part 3: Pre-defined PDO communication, Part 4: EMS controller, Part 5: Voltage converter unit, Part 6: Battery pack, Part 7: Motor control unit (under development), Part 8: Load monitoring unit (under development), Part 9: HMI unit (under development), Part 10: Security unit (under development), Part 11: Sensor unit (under development), Part 12: Gateway unit (under development), Part 13: Generator unit, Part 14: Load unit. This document represents the part 14 of the CANopen application profile for EMSs. Part 14 of the document specifies load units such as lighting, electrical motor, radio, refrigerator, washing machine, etc. Loads shall be divided into three classes: controllable loads, influenceable loads and non-controllable loads. |
2014-06-17 453 KB | DSP Login |