IG03 SIG08 Contrast media injector
13:00 to 15:00
This SIG develops and maintains technical documents for contrast media injectors.
Ron Kong, Bayer U.S.
13:00 to 15:00
Name | Date | Size | Action |
---|---|---|---|
IG03 SIG08 Contrast media injector | 2024-03-21 | 11 MB | Login |
IG03 SIG08 Contrast media injector | 2024-10-17 | 4 MB | Login |
IG03 SIG08 Contrast media injector | 2019-02-19 | 136 KB | Login |
IG03 SIG08 Contrast media injector | 2019-04-09 | 886 KB | Login |
IG03 SIG08 Contrast media injector | 2019-06-05 | 140 KB | Login |
IG03 SIG08 Contrast media injector | 2019-07-16 | 1 MB | Login |
IG03 SIG08 Contrast media injector | 2019-09-24 | 570 KB | Login |
IG03 SIG08 Contrast media injector | 2019-12-12 | 323 KB | Login |
IG03 SIG08 Contrast media injector | 2021-02-24 | 852 KB | Login |
IG03 SIG08 Contrast media injector | 2021-11-04 | 1 MB | Login |
IG03 SIG08 Contrast media injector | 2022-01-19 | 4 MB | Login |
IG03 SIG08 Contrast media injector | 2022-03-25 | 896 KB | Login |
IG03 SIG08 Contrast media injector | 2022-06-30 | 668 KB | Login |
IG03 SIG08 Contrast media injector | 2022-09-09 | 2 MB | Login |
IG03 SIG08 Contrast media injector | 2022-11-30 | 997 KB | Login |
IG03 SIG08 Contrast media injector | 2023-03-08 | 460 KB | Login |
IG03 SIG08 Contrast media injector | 2023-05-24 | 297 KB | Login |
Title | Details | Published Size |
Status Action |
---|---|---|---|
CiA 425-1 version 2.1.0 CANopen application profile for medical diagnostic add-on modules – Part 1: General definitions |
ScopeThe CANopen application profile for medical diagnostic add-on modules includes several parts: Part 1 describes general definitions. Part 2 defines the profile for injector devices. Devices compliant to these profiles use communication techniques, which conforms to those described in the CANopen application layer and communication profile (CiA 301). In addition, medical devices and sub-systems may use communication techniques, which conform to those described in the CANopen additional application layer functions specification (CiA 302). These specifications should be consulted in parallel to these device profile specifications. |
2011-06-03 447 KB | DS Login |
CiA 425-2 version 2.4.0 CANopen application profile for medical diagnostic add-on modules – Part 2: Injector |
ScopeThis profile specifies the CANopen device profile for injector interface units. This profile covers injectors connected to a medical diagnostic system (angiography, computer tomography, and other medical diagnostic devices), which provide CANopen Manager functionality. If a safety-related communication is required, the injector device is compliant to the CANopen framework for safety-related communication (EN 50325-5). The definition of SRDOs (safety-related data objects) is not in the scope of this document. A prerequisite for the conformity to this CANopen device profile is conformity with the CANopen communication profile (CiA 301). Additionally, in the case that the module is programmable it shall conform to the framework for programmable CANopen devices (CiA 302). These specifications should be consulted in parallel to this device profile specification. |
2017-11-17 2 MB | DSP Login |
CiA 425-2 version 2.4.3 CANopen application profile for medical diagnostic add-on modules Part 2: Injector |
Scope |
2023-05-24 2 MB | WD Login |
CiA 425-2 version 2.2.0 CANopen application profile for medical diagnostic add-on modules – Part 2: Injector |
ScopeThis profile specifies the CANopen device profile for injector interface units. This profile covers injectors connected to a medical diagnostic system (angiography, computer tomography, and other medical diagnostic devices), which provide CANopen Manager functionality. If a safety-related communication is required, the injector device shall be compliant to the CANopen framework for safety-related communication (CiA 304). A prerequisite for the conformity to this CANopen device profile is conformity with the CANopen communication profile (CiA 301). Additionally, in the case that the module is programmable it shall conform to the framework for programmable CANopen devices (CiA 302). These specifications should be consulted in parallel to this device profile specification. |
2011-06-03 2 MB | DS Login |
CiA 312-4 version 1.0.1 CANopen profile conformance test plan – Part 4: Contrast media injectors |
Scope |
2012-05-20 2 MB | WD Login |
CiA 312-4 version 1.0.0 CANopen profile conformance test plans - Part 4: Contrast media injectors |
ScopeThis part of the test plan specifies the additional tests for contrast media injectors, which shall be tested for conformity according to CANopen application profile for medical diagnostic add-on modules (CiA 425-1 version 2.0. and CiA 425-2 version 2.0.2). The additional tests verify entries in EDS and object dictionary, which are defined in CANopen application profile for medical diagnostic add-on modules. Furthermore additional test steps verify the implementation of the device finite state automata and further object coherences, which are defined in application profile for medical diagnostic add-on modules. To achieve a certain level of conformity the DUT shall pass the corresponding tests defined in CANopen conformance test plan, CiA 312-1, plus those defined in this test plan. |
2009-01-16 2 MB | DSP Login |